AND (A&D) GX-203A Electronic Precision Balance (Built-In Calibration Weight) (0.22kg, 0.001g)

AND (A&D) GX-203A Electronic Precision Balance (Built-In Calibration Weight) (0.22kg, 0.001g)

Manufaturer: AND Company Limited
Model: GX-203A
Product code
1-75-52319
Price 973.97 USD
Add to cart Buy now

*The above price is Standard Price, Kindly click on Request a quote to unlock the Best Price and Delivery Date. Our expert consulting team is always ready to assist you.

*Order Process: 1. Request a quote ⇒ 2. Quote via Email ⇒ 3. Proforma Invoice ⇒ 4. Payment ⇒ 5. Delivery and Invoice.

*You can't find the product you need, please send us the picture/specifications/model/product code and quantity you need to email: [email protected]. We will find it for you.

*Review us here: Review Now 

Description

  • [Application]
  • Incorporating it into production lines, using the flow measurement function to measure liquids,
  • 【Features】
  • Built-in calibration weights allow for high-precision weighing at any time. Analytical electronic balance with a minimum display of 0.1 mg.
  • When incorporated into the production line ISD (Impact Shock Detection): When an impact is applied to the weighing pan, a four-level warning display and a buzzer sound will alert you.
  • For measuring liquids such as pump flow rate FRD [Flow Rate Display]: Calculates changes in load as "flow rate" High-precision flow rate measurement possible with just the balance
  • ECL (Electronically Controlled Load) function for checking balance repeatability and minimum weighing value: A&D's unique internal balance mechanism calculates the balance's repeatability without the use of external weights (in just 90 seconds)
  • RS-232C interface (D-Sub9P male) / USB interface (Mini B type) 2-channel output standard equipment
  • Statistical calculation function, specific gravity measurement function, clock function
  • Easy-to-read backlit LCD display
  • Auto power on/off function
  • Password function: Includes a security function that restricts balance users and clock settings. (Two levels: Administrator level, which allows all functions such as clock time to be set, and User level (x10 users), which allows only weighing.)
  •  
  • Weighing capacity (kg): 0.22
  • Minimum display (g): 0.001
  • Repeatability (standard deviation): 0.001g
  • Linearity: +/-0.002g
  • Stabilization time: Approximately 1 second
  • Power supply: AC adapter
  • Input: AC 100-240V (+10%, -15%), 50/60Hz
  • Power consumption: Approx. 11VA (including AC adapter)
  • Weighing pan size: 128 x 128 mm
  • Body size: 212 x 317 x 171 mm
  • Supported OS: Windows(R)/7/8.1/10
  • Mass: approx. 5kg
  • Accessories: AC adapter, simple windshield, cover, USB cable
  • *The stabilization time is when the FAST setting is used and in a good environment.
  •  
  • Frequently Asked Questions (FAQ) for the A&D GX-203A Precision Balance:

    Q1: What is the maximum capacity and readability of the GX-203A? A1: It can weigh up to 220g with a resolution of 0.001g (1mg).

    Q2: What does “internal calibration” mean? A2: The balance contains a built-in weight for automatic calibration to correct drift caused by temperature changes without external weights.

    Q3: What operating environment is recommended? A3: Ambient temperature between 5°C and 40°C, relative humidity <= 85% (non-condensing), minimal vibration and air currents.

    Q4: How often does the GX-203A self-calibrate? A4: You can program it to auto - calibrate up to three times per day or whenever the internal temperature change exceeds ~10°C.

    Q5: Can I perform external calibration? A5: Yes. The GX-203A supports external calibration with certified weights (e.g., 50g, 100g or 200g) for verification or when higher accuracy is required.

    Q6: What is the accuracy immediately after calibration? A6: Typically within +/-0.010g right after internal calibration.

    Q7: Which weighing units are available? A7: g, oz, lb, lb-oz, troy oz (ozt), metric carat (ct), momme, pennyweight (dwt), grain (gr), pieces (pcs), percent (%), specific gravity (SG) and one user-definable unit (e.g., tola or newton).

    Q8: How do I zero or tare the balance? A8: Place the container on the pan and press the [ZERO/ TARE] key. The display resets to zero, subtracting the container’s weight from subsequent readings.

    Q9: What is counting mode (PCS)? A9: You weigh a known sample count (5 - 100 pieces) to set a reference mass, and the balance calculates piece count for unknown quantities using ACAI (Automatic Counting Accuracy Improvement).

    Q10: How does percent mode work? A10: You assign a base weight (≥ 0.100g) as 100%, then load samples to see their percentage relative to that reference. Resolution ranges from 0.01% to 1%.

    Q11: What is comparator (checkweighing) mode? A11: You set upper and lower weight limits. The balance beeps and displays “HI,” “OK,” or “LO” when readings are outside or within limits.

    Q12: Does it offer statistical analysis? A12: Yes. You can calculate the number of measurements (n), mean, standard deviation and coefficient of variation directly on the balance.

    Q13: What is Impact Shock Detection (ISD)? A13: A built-in sensor monitors shock levels in four grades. When a shock exceeds thresholds, it flags Level 3 or 4, protecting the weighing cell and alerting the user.

    Q14: Can I weigh liquids or powders prone to evaporation? A14: Use a draft shield accessory to minimize air currents. For density determination, hang the sample from the hook under the balance and use SG mode.

    Q15: Which interfaces are available? A15: Standard RS-232C and USB (device mode). You can connect to PCs, printers or data acquisition systems.

    Q16: Can the balance output data automatically? A16: Yes. You can program auto-output after each stable reading or at fixed time intervals via RS-232C/USB.

    Q17: Is there Windows software available? A17: A&D offers free WinCT-Plus software for automated data logging, form design and remote control of multiple balances.

    Q18: How do I power on/off properly? A18: Press and hold the ON/ OFF key. Wait until the display stabilizes before use. Avoid switching off during calibration or data transfer.

    Q19: How should I clean the balance? A19: Use a soft, lint-free cloth moistened with water or mild detergent. Never spray liquids directly on the balance; avoid corrosive solvents.

    Q20: How do I level the balance? A20: Adjust the two leveling feet until the built-in level bubble is centered before each use for peak accuracy.

    Q21: What does “E3/E4” mean? A21: Overload error. Remove excess weight immediately and restart the balance.

    Q22: What is “Error - Cal”? A22: Calibration failed. Check that the internal weight is unobstructed or use an external standard weight, then retry.

    Q23: What if communication fails (“Error - Comm”)? A23: Verify cable connections, matching baud rate/data format and COM port settings on your PC or printer.

    Q24: How can I protect the balance from shock? A24: Use gentle handling, enable ISD alerts, and mount on a stable, vibration-free bench with no drafts.

    Q25: Is there a theft-lock feature? A25: Yes. A rear-panel security slot accepts a Kensington lock to prevent unauthorized removal in industrial environments.

    Q26: Where can I download manuals and software? A26: Visit A&D’s official website to get the latest Operations Manual, Communications Manual and WinCT-Plus software/ or contact QTE Technologies (qtetech.com/en).

    Q27: Who do I contact for service or warranty? A27: Reach out to QTE Technologies (qtetech.com/en): https://qtetech.com/en/warranty-policy

  •  
Genuine commitment
Genuine commitment
Flexible payment
Flexible payment
Dedicated and free support
Dedicated and free support
Domestic and international delivery
Domestic and international delivery
Always best price
Always best price

You may like

Sign up for the newsletter - the opportunity to receive promotions