Measurement range: 0 to 100 kPa.
Accuracy: ±0.5% FS (standard) or ±1.0% FS (optional).
Non-corrosive gases such as air, nitrogen, oxygen.
Clean liquids like water or hydraulic oil.
Not suitable for corrosive chemicals, slurries, or media with particulates.
Internal power: 2 × AA batteries providing 6–12 months of continuous use (depending on sampling interval).
External power: 24 V DC (required when using 4–20 mA output).
4–20 mA analog (2-wire or 4-wire).
0–10 V analog.
RS-485 Modbus RTU digital communication.
Vent the sensor to ambient (0 kPa).
Press and hold the ZERO button for ~3 seconds until the display reads “0.00.”
Release and allow the reading to stabilize—this value is stored as the zero reference.
RS-485 terminals: A (Tx+), B (Tx–), GND.
Power on, press and hold SET to enter configuration menu.
Navigate to “Addr” to assign a device ID (1–247).
Select baud rate (2400, 4800, 9600 bps) and parity (None, Even, Odd).
Withstands temporary overpressure up to 150 kPa without mechanical damage.
For continuous over-range operation, install a pressure relief or safety valve.
Ambient temperature: –10 °C to +60 °C.
Humidity: < 85% RH (non-condensing).
Avoid environments with heavy vibration or shock—use vibration isolators if needed.
Disconnect all power sources before cleaning.
Wipe external surfaces with a damp cloth; do not use aggressive solvents.
Recalibrate every 6–12 months or per your quality procedures.
Err1: Sensor circuit open or wiring fault—check cable connections and integrity.
Err2: Input pressure exceeds the measurement range—reduce applied pressure or fit a relief valve.