Kiriyama glass EX92A-1-1 Soxhlet Extractor 100mL

Kiriyama glass EX92A-1-1 Soxhlet Extractor 100mL

Manufaturer: Kiriyama glass
Model: EX92A-1-1
Product code
1-85-57458
Price 312.85 USD
Add to cart Buy now

*The above price is Standard Price, Kindly click on Request a quote yes to unlock Competitive Pricing and Delivery Dates - Check Availability. Our expert consulting team is always ready to assist you within one business day.

*Order Process: 1. Request a quote ⇒ 2. Quote via Email ⇒ 3. Proforma Invoice ⇒ 4. Payment ⇒ 5. Delivery and Invoice.

*We deliver to your doorstep under DAP terms. Customs clearance is for your account.

Payment-Delivery

*You can't find the product you need, please send us the picture/specifications/model/product code and quantity you need to email: [email protected]. We will find it for you.

*Review us here: Review Now 

Description

  • Model number: EX 92 A-1-1
  • Flasks capacity (mL): 100
  • Compatible paper filtration cylinder size (mm): 24 x 90
  • Top (sliding): 29/42
  • Bottom (sliding): 15/25
  • * filtration cylinder is not included
  • * Stamps and clamps are sold separately.
  • Frequently Asked Questions About the Kiriyama Glass EX92A-1-1 Soxhlet Extractor (100 mL):

    General Information

    1. What is the Kiriyama Glass EX92A-1-1 Soxhlet extractor?

    The EX92A-1-1 is a 100 mL continuous solvent extraction setup made of borosilicate glass. It consists of a Soxhlet chamber, a 100 mL round-bottom flask, and an Allihn condenser, all joined with standard ground glass connectors.

    2. Which components are included in the EX92A-1-1 kit?

  • 100 mL Soxhlet extraction tube (EX92A-1)

  • 100 mL round-bottom flask with GND 24/29 joint

  • Allihn condenser with upper and lower GND 24/29 joints

  • Optional support stand and clamps (sold separately)

  • Technical Specifications

    3. What is the maximum solvent capacity?

    The round-bottom flask holds up to 100 mL of solvent. Typical working volumes range from 50 to 70 mL to allow for proper vaporization and reflux.

    4. How much sample can I process at once?

    A standard cellulose thimble (24 × 90 mm) fits inside the Soxhlet chamber and accommodates approximately 5–10 g of dry, ground sample, depending on thimble porosity.

    5. What are the ground glass joint sizes?

  • Flask to Soxhlet tube: GND 24/29

  • Soxhlet tube to condenser: GND 24/29

  • Condenser hose connections: standard 6 mm or 8 mm outer-diameter tubing

  • Principle and Operation

    6. How does a Soxhlet extraction work?

  • The solvent in the flask is heated to reflux.

  • Vapor travels up into the condenser and drips back into the Soxhlet chamber.

  • The solvent accumulates around the sample and extracts compounds.

  • Once full, the solvent siphons back into the flask, carrying dissolved analytes.

  • The cycle repeats until extraction is complete.

  • 7. What is a typical extraction procedure?

  • Dry your sample in an oven at 80 °C to remove moisture.

  • Load the thimble and place it in the Soxhlet tube.

  • Add solvent (50–70 mL) to the flask and assemble the apparatus.

  • Begin gentle heating to maintain a steady drip rate (3–4 drops per second).

  • Run for 6–8 hours or until extracts appear clear.

  • Cool, dismantle, and recover the solvent for further processing.

  • Assembly and Setup

    8. How do I assemble the EX92A-1-1 extractor?

  • Secure the flask on a heating mantle or water bath.

  • Attach the Soxhlet tube to the flask via the GND 24/29 joint.

  • Place the condenser atop the Soxhlet tube and tighten with a clamp.

  • Connect inlet and outlet hoses to the condenser (cold water in at the bottom, out at the top).

  • Ensure all joints are snug and supported.

  • 9. What solvent volume and heating settings work best?

  • Fill the flask to no more than two-thirds capacity to prevent bumping.

  • Use a heating mantle or oil bath set to yield mild reflux—avoid vigorous boiling to reduce bumping and vapor loss.

  • Maintenance and Cleaning

    10. How do I clean and maintain the unit?

  • Disassemble and rinse each glass part with an appropriate solvent (acetone or ethanol).

  • Use a soft brush for stubborn residues inside the Soxhlet chamber.

  • Dry components at 105 °C or allow to air-dry in a dust-free environment.

  • Inspect ground joints for chips or roughness before each use.

  • Safety Precautions

    11. What safety measures should I take?

  • Wear chemical-resistant gloves, safety goggles, and a lab coat.

  • Operate under a fume hood to avoid inhaling solvent vapors.

  • Check all glassware for cracks and ensure joints are properly lubricated.

  • Never allow the flask to run dry while heating to prevent thermal shock.

  • Troubleshooting

    12. What should I do if the system leaks solvent vapor?

  • Ensure ground glass joints are clean and lightly greased with vacuum grease.

  • Replace any chipped or scratched joints.

  • Tighten clamps to stabilize connections without overtightening.

  • 13. Why isn’t condensation occurring efficiently?

  • Increase coolant flow through the condenser.

  • Check that water inlet is at the condenser’s lowest port and outlet at the top.

  • Confirm the condenser jacket is free from blockages or air pockets.

  • Applications

    14. What applications is this extractor suited for?

  • Fat and oil extraction from plant material, soils, or food products

  • Isolation of active ingredients from herbal samples

  • Preparation of environmental samples for pesticide or pollutant analysis

  • Ordering and Accessories

    15. Can I upgrade to a larger flask size?

    Yes. You can substitute a 250 mL or 500 mL round-bottom flask with the same GND 24/29 joint to increase solvent capacity and process larger sample loads.

    16. Where can I purchase spare parts and accessories?

    Contact QTE Technologies.

You may like

Sign up for the newsletter - the opportunity to receive promotions