HIOKI CM4373-50 AC/ DC Clamp Meter (600.0A/ 2000A)

HIOKI CM4373-50 AC/ DC Clamp Meter (600.0A/ 2000A)

Manufaturer: HIOKI E. E. CORPORATION
Model: CM4373-50
Product code
111-67796
Price 548.31 USD
Add to cart Buy now

*The above price is Standard Price, Kindly click on Request a quote to unlock the Best Price and Delivery Date. Our expert consulting team is always ready to assist you.

*Order Process: 1. Request a quote ⇒ 2. Quote via Email ⇒ 3. Proforma Invoice ⇒ 4. Payment ⇒ 5. Delivery and Invoice.

*You can't find the product you need, please send us the picture/specifications/model/product code and quantity you need to email: [email protected]. We will find it for you.

*Review us here: Review Now 

Description

  • Compatible with GENNE CT Cross's harmonic analysis and event recording functions!
  • Contributes to troubleshooting and improved work efficiency! (Requires the optional Z3210)
  • Compatible with CAT III 2000V!
  • Safely measure increasingly high voltage PV equipment! (Requires separate optional P2000)
  • The included cap-integrated test leads make it even more convenient and safe.
  • DC and AC current compatible, can measure up to 600A
  • AC/DC automatic discrimination
  • Simply set the rotary switch to "current measurement" or "voltage measurement" and the instrument will automatically detect AC/DC and measure.
  • Even in places where AC and DC are mixed, there is no need to switch between rotary switches, preventing measurement errors.
  • INRUSH (inrush current) measurement
  • Simultaneously measures and displays the effective value and maximum peak value of inrush current that occurs when starting a motor or during welding current.
  • It automatically detects and measures the duration of inrush current, allowing for more accurate measurements than typical clamp meters with a fixed 100ms measurement.
  • Product design and construction that takes operability and convenience into consideration
  • We want our Made in Japan products, developed and produced in Ueda, Shinshu, to be used by customers all over the world, so our product design and construction has been tailored to enhance operability and convenience based on customer needs.
  • The rotary switch on the main unit is designed so that it can be operated with one hand even while wearing work gloves.
  • In addition, it is equipped with a white backlight so that measurement values can be clearly seen even in dark places, and a wide-viewing angle display so that measurement values can be read from any angle.
  • The measurement category is CATIV600V.
  • Wide range of measurement targets
  • To ensure the safe use of measuring instruments, the IEC 61010 safety standard classifies safety levels into measurement categories (CAT II to CAT IV) according to the location of use.
  • The higher the number, the wider the range of measurements.
  •  
  • DC current range: 600.0A/2000A, basic accuracy: ±1.3% rdg. ±0.3A (600A range)
  • AC current range: 600.0A/2000A (10-1kHz, true RMS rectification), basic accuracy 45-66Hz/±1.3% rdg. ±0.3A (at 600A)
  • Crest factor: 600.0A range/3 or less, 2000A range/2.84 or less
  • AC + DC current range: 600.0A/2000A (10 to 1kHz, true RMS rectification), basic accuracy DC, 45-66Hz / ±1.3% rdg. ±1.3A (at 600A)
  • DC voltage range: 600.0mA to 1000V (600.0V to 2000V when using P2000)
  • AC voltage range: 6,000 V to 1,000 V, 4 ranges (15 to 1 kHz, true RMS rectification), basic accuracy 45-66 Hz / ±0.9% rdg. ±0.003 V (at 6 V)
  • AC+DC voltage range: 6,000 V to 1,000 V, 4 ranges, basic accuracy DC, 45-66 Hz / ±1.0% rdg. ±0.023 V (at 6 V)
  • Resistance range: 600.0Ω to 6.000MΩ, 5 ranges, basic accuracy: ±0.7% rdg. ±0.5Ω (at 600Ω)
  • Capacitance range: 1.000μF to 1000μF, 4 ranges, basic accuracy: ±1.9% rdg. ±0.005μF (at 1μF)
  • Frequency range: 9.999Hz to 999.9Hz, 3 ranges, basic accuracy: ±0.1% rdg. ±0.003Hz (at 9.999Hz)
  • Temperature (K): -40.0 to 400.0°C, Accuracy: ±0.5% rdg. ±3.0°C + temperature probe accuracy
  • Voltage detection: Hi/AC40V~600V, Lo/AC80V~600V, 50/60Hz
  • Other functions: DC power, continuity check, diode check, automatic AC/DC detection, positive/negative DC current and voltage judgment, maximum/minimum/average/maximum peak value/minimum peak value display, low-pass filter, display value hold, backlight, auto power save, buzzer sound, zero adjustment, etc.
  • Dustproof and waterproof: IP54 (storage or current measurement of insulated conductors)
  • Power supply: 2 x AAA alkaline batteries (LR03); Continuous use time: Approx. 40 hours (Z3210 not installed), Approx. 24 hours (Z3210 installed and wireless communication); Other specified conditions: AC100A measurement, LCD backlight OFF, reference value at 23°C
  • Measurable conductor diameter: φ55mm
  • Jaw dimensions: 92W x 18D mm
  • Dimensions: 65W x 250H x 35D mm
  • Mass: 530g
  • Operating temperature range: -25℃ to 65℃
  • Accessories: Test lead L9300 x 1, Carrying case C0203 x 1, AAA alkaline battery (LR03) x 2, Instruction manual x 2, Usage precautions x 1
  •  
Genuine commitment
Genuine commitment
Flexible payment
Flexible payment
Dedicated and free support
Dedicated and free support
Domestic and international delivery
Domestic and international delivery
Always best price
Always best price

You may like

Viewed recently

Sign up for the newsletter - the opportunity to receive promotions