GASTEC 180L Gas Detector Tube Amines

GASTEC 180L Gas Detector Tube Amines

Manufaturer: GASTEC
Model: 180L
Product code
1-75-53330
Price 21.64 USD
Add to cart Buy now

*This is standard price, please click "Request a quote" to see the actual price.

*You can't find the product you need, please send us the picture/specifications/model/product code and quantity you need to email: info@qtetech.com.vn. We will find it for you.

Description

  • Detecting tube name: 180L amines
  • Number of measurements of 1 box: 10
  • Expiration date (year): 2
  •  
  • Measurement gas name: N,N-Diethylethanolamine
  • Measurement range: 0.6 - 12ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: N,N-Dimethylethylamine
  • Measurement range: 0.3 - 6ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: N.N-Dimethylethanolamine
  • Measurement range: 0.65 - 13ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: N-Ethylmorpholine
  • Measurement range: 0.3 - 6ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: n- Butylamine
  • Measurement range: 0.55 - 11ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Amines
  • Measurement range: 0.5 - 10ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: -
  •  
  • Measurement gas name: Isopropylamine
  • Measurement range: 0.45 - 9ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Ethanolamine (monoethanolamine)
  • Measurement range: 1.95 - 39ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Ethylamine
  • Measurement range: 0.45 - 9ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Ethylenediamine
  • Measurement range: 0.9 - 18ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Di -n- Butylamine
  • Measurement range: 0.4 - 8ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Diisopropylamine
  • Measurement range: 0.3 - 6ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Diethylamine
  • Measurement range: 0.45 - 9ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Diethylenetriamine
  • Measurement range: 0.95 - 19ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Cyclohexylamine
  • Measurement range: 0.5 - 10ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Dipropylamine
  • Measurement range: 0.35 - 7ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Dimethylaminopropylamine
  • Measurement range: 0.6 - 12ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Dimethylamine
  • Measurement range: 0.45 - 9ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Tetramethylenediamine
  • Measurement range: 0.8 - 16ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Triethylamine
  • Measurement range: 0.3 - 6ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Trimethylamine
  • Measurement range: 0.25 - 5ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Propylamine
  • Measurement range: 0.5 - 10ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Propylenimine
  • Measurement range: 0.35 - 7ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Hexamethyleneimine
  • Measurement range: 1.55 - 31ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Hexylamine
  • Measurement range: 0.65 - 13ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Pentamethylenediamine
  • Measurement range: 0.75 - 15ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Methylamine
  • Measurement range: 0.5 - 10ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
  •  
  • Measurement gas name: Morpholine
  • Measurement range: 0.5 - 10ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used
Genuine commitment
Genuine commitment
Flexible payment
Flexible payment
Dedicated and free support
Dedicated and free support
Domestic and international delivery
Domestic and international delivery
Always best price
Always best price

You may like

Sign up for the newsletter - the opportunity to receive promotions