Manufaturer: | ENDO KOGYO |
Model: | EHW-120R |
*The above price is Standard Price, Kindly click on Request a quote to unlock the Best Price and Delivery Date. Our expert consulting team is always ready to assist you.
*Order Process: 1. Request a quote ⇒ 2. Quote via Email ⇒ 3. Proforma Invoice ⇒ 4. Payment ⇒ 5. Delivery and Invoice.
*You can't find the product you need, please send us the picture/specifications/model/product code and quantity you need to email: [email protected]. We will find it for you.
*Review us here: Review Now
The EHW-120R is an air-powered wire hoist designed to lift, lower, and hold loads up to 120kg with a 1.9m stroke.
It’s widely used in automotive assembly, machinery maintenance, chemical plants, clean rooms, and any production line requiring ergonomic lifting and precise positioning.
Maintain a clean, dry, oil-free compressed air supply at 0.5 - 0.6MPa to ensure smooth operation and cylinder longevity.
Recommended minimum airflow is 50 L/min, with piping of at least φ10mm (φ12mm preferred) to minimize pressure drop.
- Securely hang the balancer from a structural beam or trolley rated at least four times the maximum load.
- Install an air shut-off valve within 1m of the balancer for emergency isolation.
- Route the air supply tubing straight to the inlet, avoiding sharp bends or kinks.
- Tighten all fittings and check gaskets before pressurizing.
- Open the air shut-off valve and confirm system pressure at 0.6MPa.
- Use the pendant pushbutton to raise or lower the load; higher buttons increase speed, lower buttons decrease speed.
- Release all buttons to lock the load in position automatically via the internal locking valve.
- Adjust fine-tuning speed control knob on the pendant for precise positioning.
- Daily: Inspect for air leaks at fittings and clean dust off the hoist body.
- Weekly: Lubricate guide rollers and seals with silicone oil.
- Monthly: Disassemble and inspect one-way valve and replace O-rings if showing wear.
- Yearly: Calibrate lifting force and verify lock-valve performance; undergo safety inspection.
The EHW-120R incorporates an internal locking valve that engages if air pressure falls, ensuring the load descends slowly rather than free-falling.
A reverse-winding prevention device stops the wire from unwinding in the wrong direction and automatically halts the motor when the full 1.9m rope is extended.
Symptom |
Possible Cause |
Recommended Action |
---|---|---|
Load won’t lift or moves slowly |
Insufficient air pressure or clogged filter |
Increase to 0.6MPa, clean or replace air filter |
Load descends too quickly |
Speed control valve misadjusted or faulty |
Adjust knob or replace control valve |
Continuous hissing or air leak |
Worn O-rings or loose fittings |
Replace O-rings, tighten connections |
Hoist doesn’t stop at full stroke |
Rope-end auto-stop mechanism jammed |
Inspect and clean reverse-winding device |