AS ONE 4-794-01 THA-01M Digital Temperature And Humidity Monitor (Large Monitor) (0 - 60oC, 10 - 90%RH)

AS ONE 4-794-01 THA-01M Digital Temperature And Humidity Monitor (Large Monitor) (0 - 60oC, 10 - 90%RH)

Manufaturer: AS ONE
Model: THA-01M
Product code
111-67804
Price 68.54 USD
Add to cart Buy now

*The above price is Standard Price, Kindly click on Request a quote to unlock the Best Price and Delivery Date. Our expert consulting team is always ready to assist you.

*Order Process: 1. Request a quote ⇒ 2. Quote via Email ⇒ 3. Proforma Invoice ⇒ 4. Payment ⇒ 5. Delivery and Invoice.

*We deliver to your doorstep under DAP terms. Customs clearance is for your account.

*You can't find the product you need, please send us the picture/specifications/model/product code and quantity you need to email: [email protected]. We will find it for you.

*Review us here: Review Now 

Description

  • The large digital display and the depth of the main unit make it convenient for stationary use.
  • It measures relative humidity over a wide range (10 to 90% RH) with high accuracy (±3%).
  • You can check the remaining battery level at a glance.
  • Large LCD screen for excellent visibility
  •  
  • Measurement range: Temperature: 0 to 60°C, Humidity: 10 to 90% RH
  • Display resolution: Temperature/0.1℃, Humidity/1%RH
  • Reference display accuracy:
  • Temperature/±0.3℃ (Typ), ±0.5℃ (Max) (0 to 60℃)
  • Humidity/±3%RH (Typ), ±5%RH (Max) (25℃・10~90%RH)
  • *The calibration point for this unit is 50%RH@25℃ (temperature ±0.5℃/humidity ±5%).
  • Size: Main unit: 110 x 32 x 77 mm, Display unit: 52 x 40 mm
  • Material: ABS resin
  • Sampling interval: 30 seconds
  • Power supply: 2 AA batteries (included for testing)
  • Weight: Approx. 200g (including 2 batteries)
  • RoHS2 (EU)2015/863 compliant
  • Frequently Asked Questions (FAQ) for AS ONE 4-794-01 THA-01M Digital Temperature and Humidity Monitor:

    Below are common questions and answers about the AS ONE 4-794-01 THA-01M (0–60 °C, 10–90 %RH).

  • 1/ What is the measurement range of the THA-01M?

    Temperature: 0 °C to 60 °C Humidity: 10 %RH to 90 %RH

  • 2/ What display resolution does it offer?

    Temperature: 0.1 °C Humidity: 1 %RH

  • 3/ How accurate are the readings?

    Temperature: ±0.3 °C (typical), ±0.5 °C (max) within 0–60 °C Humidity: ±3 %RH (typical), ±5 %RH (max) at 25 °C and 10–90 %RH

  • 4/ How often does it sample the environment?

    The unit updates readings every 30 seconds

  • 5/ What type of sensor is integrated?

    A capacitive humidity sensor paired with a precision thermistor for temperature measurement ensures stable, accurate performance

  • 6/ What are the physical dimensions and weight?

    Main body: 110 × 32 × 77 mm Display area: 52 × 40 mm Weight: Approx. 200 g (including two AA batteries)

  • 7/ What material is the enclosure made of?

    Durable ABS resin, providing impact resistance and insulating properties

  • 8/ How is it powered and how long do batteries last?

    Powered by two AA batteries (included for testing) Typical battery life ranges from 6 months to 1 year, depending on usage patterns and operating conditions

  • 9/ Can I see the remaining battery level?

    Yes, a battery-low indicator is built into the LCD display for at-a-glance status monitoring

  • 10/ Does the THA-01M have alarm outputs?

    No. This model provides real-time display only and does not offer configurable alarm outputs or thresholds.

  • 11/ Does it store historical data or log readings?

    No. Readings are shown live on the display and are not recorded internally. For data logging, consider AS ONE’s dedicated data-logger models.

  • 12/ Are there any communication interfaces (USB, RS-232, Bluetooth)?

    No. The THA-01M is designed for stationary observation without external data-transfer ports.

  • 13/ How can I install or mount the unit?

    It features both a wall-mount slot on the back and a built-in stand for desktop placement.

  • 14/ What operating conditions should be observed?

    Ambient conditions: 0–60 °C and 10–90 %RH. Avoid direct sunlight, excessive dust, or condensation to protect sensor integrity.

  • 15/ What are the recommended storage conditions?

    Store at –10 °C to 60 °C and below 90 %RH. Keep away from corrosive chemicals and liquid water.

  • 16/ How do I perform a reset or factory restore?

    Remove both batteries, wait one minute, then reinstall them. This clears any temporary states and returns the unit to default display mode.

  • 17/ How should I clean and maintain the device?

    Wipe the enclosure and screen with a soft, dry cloth. Do not use solvents or immerse the unit in liquids. Inspect the sensor tip gently for dust buildup and clean with compressed air if needed.

  • 18/ Does the THA-01M comply with any safety or environmental standards?

    It is RoHS 3 (EU 2015/863) compliant, ensuring it is free from regulated hazardous substances

  • 19/ What accessories come with the monitor?

    Included: two AA batteries for initial operation. No carrying case or additional mounting hardware is provided.

  • 20/ Where can I obtain detailed datasheets or certificates?

    Technical datasheets, calibration certificates, and instruction manuals are available upon request from AS ONE or authorized distributors as QTE Technologies (qtetech.com/en)

  • 21/ How do I request a quote or place an order?

    Contact your local AS ONE distributor (e.g., QTE Technologies - qtetech.com/en) with product code 4-794-01 THA-01M, desired quantity, and delivery address for a formal quotation.

  • 22/ What is the typical lead time for delivery?

    Lead times vary by region and stock availability but generally range from 2 to 4 weeks after order confirmation.

  • 23/ Can the THA-01M be used outdoors?

    It is designed for controlled indoor environments. Extended exposure to UV light, rain, or extreme weather may degrade performance and void the warranty.

  • 24/ Are calibration services available?

    Yes. Periodic calibration (every 6–12 months) is recommended. Send the unit to an accredited calibration laboratory or use certified reference standards for in-house checks.

Genuine commitment
Genuine commitment
Flexible payment
Flexible payment
Dedicated and free support
Dedicated and free support
Domestic and international delivery
Domestic and international delivery
Always best price
Always best price

You may like

Sign up for the newsletter - the opportunity to receive promotions