Manufaturer: | AS ONE |
Model: | LRM18B |
*The above price is Standard Price, Kindly click on Request a quote to unlock the Best Price and Delivery Date. Our expert consulting team is always ready to assist you.
*Order Process: 1. Request a quote ⇒ 2. Quote via Email ⇒ 3. Proforma Invoice ⇒ 4. Payment ⇒ 5. Delivery and Invoice.
*You can't find the product you need, please send us the picture/specifications/model/product code and quantity you need to email: [email protected]. We will find it for you.
*Review us here: Review Now
The AS ONE 3-6689-01 LRM18B is a binocular biological microscope equipped with Plan achromatic objectives and an integrated LED illuminator. It delivers total magnifications from 40X up to 1000X, making it ideal for cell biology, histology, microbiology labs, and teaching applications. Manufacturer specifications form the basis of this overview.
Specification | Details |
---|---|
Model | AS ONE 3-6689-01 (LRM18B) |
Optical System | Plan achromatic |
Eyepieces | WF10X, field number 18 |
Objectives | 4X (N.A. 0.10), 10X (N.A. 0.25), S40X (N.A. 0.65), 100X oil (N.A. 1.25) |
Magnification Range | 40X, 100X, 400X, 1000X |
Focusing Mechanism | Coaxial coarse and fine (0.002 mm division) |
Stage | 143 × 120 mm, mechanical XY |
Condenser | Abbe N.A. 1.25 with iris diaphragm |
Illumination | White LED, brightness knob; AC 100–240 V, 50/60 Hz |
Dimensions (W×D×H) | 235 × 151 × 362 mm |
Weight | Approximately 5 kg |
Specifications are based on manufacturer data.
Total magnification is calculated by multiplying the eyepiece by the objective. With the WF10X eyepiece and supplied objectives (4X, 10X, 40X, 100X), you achieve 40X, 100X, 400X, and 1000X viewing power.
This model includes wide-field WF10X eyepieces (field number 18) and four Plan achromatic objectives:
4X (N.A. 0.10)
10X (N.A. 0.25)
S40X (N.A. 0.65)
100X oil immersion (N.A. 1.25)
An integrated white LED source offers stable, flicker-free lighting. Brightness is adjusted via a front-panel knob. The unit runs on standard AC 100–240 V, 50/60 Hz power.
Place a drop of immersion oil on the specimen.
Rotate the 100X oil objective into position.
Focus using fine adjustment only.
Upon completion, clean oil off the objective with lens paper and lens cleaner.
Use lens tissue lightly moistened with 70% ethanol.
Wipe each lens in a spiraling motion from center outward.
Blow away loose dust on the stage and condenser with a rubber bulb blower.
Store covered when not in use.
Calibration is recommended every 6–12 months or when measurements drift. Use a stage micrometer slide to verify and adjust your calibration scale or send the unit to an authorized calibration service.
Blurry image: clean lenses, ensure proper tube length, check slide thickness.
Over-illumination: reduce LED intensity or close the condenser diaphragm.
Stiff focusing: apply a drop of microscope-grade grease to the focusing rack.
Place the microscope on a stable, level bench.
Secure the base anti-skid pads.
Connect the power cord to an AC 100–240 V outlet.
Switch on the LED illuminator.
C-mount adapter for digital cameras
Phase contrast and fluorescence filter kits
Specialized stages for Petri dishes or inverted applications
Refer to your local AS ONE distributor (QTE Technologies - qtetech.com/en) for warranty terms, extended service plans, and spare parts ordering.