| Manufaturer: | Aco |
| Model: | 3116 |
*The above price is Standard Price, Kindly click on Request a quote to unlock the Best Price and Delivery Date. Our expert consulting team is always ready to assist you.
*Order Process: 1. Request a quote ⇒ 2. Quote via Email ⇒ 3. Proforma Invoice ⇒ 4. Payment ⇒ 5. Delivery and Invoice.
*We deliver to your doorstep under DAP terms. Customs clearance is for your account.
*You can't find the product you need, please send us the picture/specifications/model/product code and quantity you need to email: [email protected]. We will find it for you.
*Review us here: Review Now
The ACO 3116 is a compact, handheld vibration meter manufactured by ACO Co., Ltd. in Japan. It provides high-precision monitoring of industrial machinery vibration, acting like a “machinery doctor” for maintenance checks.
Acceleration (ACC)
Velocity (VEL)
Displacement (DISP)
Acceleration: 0.02 – 200 m/s² RMS
Velocity: 0.02 – 200 mm/s RMS
Displacement: 2 – 2,000 µm EQp-p
Acceleration: 3 Hz – 10 kHz
Velocity: 10 Hz – 1 kHz
Displacement: 10 Hz – 400 Hz
It offers a display precision of ± 5 % across its measurement ranges.
LCD with backlight (128 × 64 dots)
4-digit numeric readout
Measurement modes: RMS, EQ Peak, Peak
Bar-graph indicator (0 – 100 %)
Data hold function for freezing readings
Internal memory: up to 256 data points (4 kB)
Interfaces: RS-232C for PC/printer, AC output for chart recorder
Headphone output for real-time vibration sound monitoring
Two AAA (LR03) alkaline cells: approx. 12 hours operation
Optional AC adapter (AC-1046) for continuous use
Operating temperature: – 10 °C to + 50 °C
Relative humidity: 30 % – 90 % (non-condensing)
Size: 145 (H) × 48 (W) × 23.5 (D) mm
Weight: approx. 130 g (including batteries)
Vibration pickup TYPE 7812B (sensitivity 5 mV/m/s² ± 3 % at 100 Hz)
Magnetic mounting block and contact pin
Coiled cable with BNC connector
Hand strap, two AAA batteries, and carrying case
Instruction manual.
Yes. When input exceeds the selected range, “Over” appears on the display and the bar-graph warning flashes across four levels.
Portable headphone and auscultation stick for sound monitoring
Data management software NA-0116 for PC data reception and charting
Use the supplied coiled cable: plug the BNC connector into the meter’s input terminal and secure the pickup on the machinery surface with the magnetic block or contact pin.
Search for “ACO 3116 Instruction Manual” from ACO’s official website or contact QTE Technologies.